Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Language
Publication year range
2.
Rev Bras Ortop (Sao Paulo) ; 58(2): 231-239, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37252307

ABSTRACT

Objective This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw. Methods A 45-degree oblique fracture line was created in artificial bone samples. The first group (FULL, n = 6) was fixed using a 3.5-mm fully-threaded lag screw, while the second group (PARTIAL, n = 6) used a 3.5-mm partially-threaded lag screw. Torsional stiffness for both rotational directions were evaluated. The groups were compared based on biomechanical parameters: angle-moment-stiffness, time-moment-stiffness, maximal torsional moment (failure load), and calibrated compression force based on pressure sensor measurement. Results After loss of one PARTIAL sample, no statistically significant differences in calibrated compression force measurement were observed between both groups: [median (interquartile range)] FULL: 112.6 (10.5) N versus PARTIAL: 106.9 (7.1) N, Mann-Whitney U-test: p = 0.8). In addition, after exclusion of 3 samples for mechanical testing (FULL n = 5, PARTIAL n = 4), no statistically significant differences were observed between FULL and PARTIAL constructs in angle-moment-stiffness, time-moment-stiffness, nor maximum torsional moment (failure load). Conclusion There is no apparent difference in the initial compression strength (compression force or construct stiffness or failure load) achieved using either fully- or partially-threaded screws in this biomechanical model in high-density artificial bone. Fully-threaded screws could, therefore, be more useful in diaphyseal fracture treatment. Further research on the impact in softer osteoporotic, or metaphyseal bone models, and to evaluate the clinical significance is required.

3.
Rev. bras. ortop ; 58(2): 231-239, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449788

ABSTRACT

Abstract Objective This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw. Methods A 45-degree oblique fracture line was created in artificial bone samples. The first group (FULL, n = 6) was fixed using a 3.5-mm fully-threaded lag screw, while the second group (PARTIAL, n = 6) used a 3.5-mm partially-threaded lag screw. Torsional stiffness for both rotational directions were evaluated. The groups were compared based on biomechanical parameters: angle-moment-stiffness, time-moment-stiffness, maximal torsional moment (failure load), and calibrated compression force based on pressure sensor measurement. Results After loss of one PARTIAL sample, no statistically significant differences in calibrated compression force measurement were observed between both groups: [median (interquartile range)] FULL: 112.6 (10.5) N versus PARTIAL: 106.9 (7.1) N, Mann-Whitney U-test: p = 0.8). In addition, after exclusion of 3 samples for mechanical testing (FULL n = 5, PARTIAL n = 4), no statistically significant differences were observed between FULL and PARTIAL constructs in angle-moment-stiffness, time-moment-stiffness, nor maximum torsional moment (failure load). Conclusion There is no apparent difference in the initial compression strength (compression force or construct stiffness or failure load) achieved using either fully-or partially-threaded screws in this biomechanical model in high-density artificial bone. Fully-threaded screws could, therefore, be more useful in diaphyseal fracture treatment. Further research on the impact in softer osteoporotic, or metaphyseal bone models, and to evaluate the clinical significance is required.


Resumo Objetivo Este estudo avaliou diferenças entre parafusos com rosca total ou parcial na resistência à compressão interfragmentar inicial. Nossa hipótese era de que haveria maior perda de resistência à compressão inicial com o parafuso de rosca parcial. Métodos Uma linha de fratura oblíqua de 45 graus foi criada em amostras de osso artificial. O primeiro grupo (TOTAL, n = 6) foi fixado com um parafuso de 3,5 mm de rosca total, enquanto o segundo grupo (PARCIAL, n = 6) usou um parafuso de 3,5 mm de rosca parcial. Avaliamos a rigidez à torção em ambas as direções de rotação. Os grupos foram comparados com base nos seguintes parâmetros biomecânicos: momento de rigidez-ângulo, momento de rigidez-tempo, momento de torção máxima (carga de falha) e força de compressão calibrada com base na medida do sensor de pressão. Resultados Depois da perda de uma amostra PARCIAL, não foram observadas diferenças estatisticamente significativas na força de compressão calibrada entre os 2 grupos [mediana (intervalo interquartil)]: TOTAL: 112,6 (10,5) N e PARCIAL: 106,9 (7,1) N, com p = 0,8 segundo o teste U de Mann-Whitney). Além disso, após a exclusão de 3 amostras para testes mecânicos (TOTAL, n = 5, PARCIAL, n = 4), não foram observadas diferenças estatisticamente significativas entre os construtos TOTAL e PARCIAL quanto ao momento de rigidez-ângulo, momento de rigidez-tempo ou momento de torção máxima (carga de falha). Conclusão Não há diferença aparente na força de compressão inicial (força de compressão ou rigidez do construto ou carga de falha) com o uso de parafusos de rosca total ou parcial neste modelo biomecânico em osso artificial de alta densidade. Parafusos de rosca total podem, portanto, ser mais úteis no tratamento de fraturas diafisárias. Mais pesquisas são necessárias sobre o impacto em modelos ósseos osteoporóticos ou metafisários de menor densidade e avaliação do significado clínico.


Subject(s)
Humans , Biomechanical Phenomena , Bone Cements , Bone Screws , Fractures, Bone/surgery
4.
Can Urol Assoc J ; 16(7): E411-E414, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35230937
5.
J Arthroplasty ; 36(8): 2936-2941, 2021 08.
Article in English | MEDLINE | ID: mdl-33840542

ABSTRACT

BACKGROUND: Porous tantalum augments are versatile tools in reconstructing complex acetabular defects during revision total hip arthroplasty (THA). This study examines the clinical and radiographic outcomes of porous tantalum augments placed in the type I (flying buttress) configuration at two to 17-year follow-up in the largest cohort to-date in the literature. METHODS: We retrospectively analyzed 59 consecutive revision THAs involving the use of flying buttress augments between 2003 and 2018. The mean patient age and follow-up duration were 63.9 ± 11.6 years (range, 35-87) and 8 years (range, 2-17), respectively. The Oxford hip score was used to assess clinical outcome. The modified Moore classification was used to assess acetabular augment and shell osseointegration. Kaplan-Meier survival analysis with 95% confidence interval (CI) was used to assess implant survivorship. RESULTS: The mean Oxford hip score improved from 15.9 ± 6.2 preoperatively to 35.0 ± 6.5 at a mean follow-up of eight years (P < .0001). Radiographic assessment using the modified Moore classification demonstrated five signs of osseointegration in 49 hips (83.1%), four signs in six hips (10.2%), three signs in one hip (1.7%), and one sign in one hip (1.7%). Kaplan-Meier analysis demonstrated ten-year survivorship of 88.9% (95% CI 74.4-95.4) with all-cause revision as end point and 94.3% (95% CI 83.1-98.2) with revision for acetabular aseptic loosening as end point. CONCLUSION: Treatment of superolateral acetabular defects during revision THA using porous tantalum augments placed in the type I (flying buttress) configuration provides excellent implant survivorship and favorable clinical outcomes at mid-term follow-up. LEVEL OF EVIDENCE: Therapeutic Level IV.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Humans , Porosity , Prosthesis Failure , Reoperation , Retrospective Studies , Tantalum
6.
PLoS One ; 16(3): e0247575, 2021.
Article in English | MEDLINE | ID: mdl-33730106

ABSTRACT

INTRODUCTION: The COVID-19 pandemic has led to widespread shortages of N95 respirators and other personal protective equipment (PPE). An effective, reusable, locally-manufactured respirator can mitigate this problem. We describe the development, manufacture, and preliminary testing of an open-hardware-licensed device, the "simple silicone mask" (SSM). METHODS: A multidisciplinary team developed a reusable silicone half facepiece respirator over 9 prototype iterations. The manufacturing process consisted of 3D printing and silicone casting. Prototypes were assessed for comfort and breathability. Filtration was assessed by user seal checks and quantitative fit-testing according to CSA Z94.4-18. RESULTS: The respirator originally included a cartridge for holding filter material; this was modified to connect to standard heat-moisture exchange (HME) filters (N95 or greater) after the cartridge showed poor filtration performance due to flow acceleration around the filter edges, which was exacerbated by high filter resistance. All 8 HME-based iterations provided an adequate seal by user seal checks and achieved a pass rate of 87.5% (N = 8) on quantitative testing, with all failures occurring in the first iteration. The overall median fit-factor was 1662 (100 = pass). Estimated unit cost for a production run of 1000 using distributed manufacturing techniques is CAD $15 in materials and 20 minutes of labor. CONCLUSION: Small-scale manufacturing of an effective, reusable N95 respirator during a pandemic is feasible and cost-effective. Required quantities of reusables are more predictable and less vulnerable to supply chain disruption than disposables. With further evaluation, such devices may be an alternative to disposable respirators during public health emergencies. The respirator described above is an investigational device and requires further evaluation and regulatory requirements before clinical deployment. The authors and affiliates do not endorse the use of this device at present.


Subject(s)
COVID-19/prevention & control , Equipment Design/instrumentation , Filtration/instrumentation , Pandemics/prevention & control , Personal Protective Equipment , Respiratory Protective Devices , Ventilators, Mechanical , Equipment Reuse , Face , Humans , Materials Testing/instrumentation , N95 Respirators , Occupational Exposure/prevention & control , Printing, Three-Dimensional/instrumentation , SARS-CoV-2/pathogenicity
7.
3D Print Med ; 6(1): 35, 2020 Nov 23.
Article in English | MEDLINE | ID: mdl-33230665

ABSTRACT

BACKGROUND: As the healthcare system faced an acute shortage of personal protective equipment (PPE) during the COVID-19 pandemic, the use of 3D printing technologies became an innovative method of increasing production capacity to meet this acute need. Due to the emergence of a large number of 3D printed face shield designs and community-led PPE printing initiatives, this case study examines the methods and design best optimized for community printers who may not have the resources or experience to conduct such a thorough analysis. CASE PRESENTATION: We present the optimization of the production of 3D printed face shields by community 3D printers, as part of an initiative aimed at producing PPE for healthcare workers. The face shield frames were manufactured using the 3DVerkstan design and were coupled with an acetate sheet to assemble a complete face shield. Rigorous quality assurance and decontamination protocols ensured community-printed PPE was satisfactory for healthcare use. CONCLUSION: Additive manufacturing is a promising method of producing adequate face shields for frontline health workers because of its versatility and quick up-start time. The optimization of stacking and sanitization protocols allowed 3D printing to feasibly supplement formal public health responses in the face of a global pandemic.

SELECTION OF CITATIONS
SEARCH DETAIL
...